Multispectrum IR Flame Detector AUTROFLAME X3301 – Det-Tronics

Det-tronics X3301 Multispectrum IR Flame Detector X3301S4M13W2

The det-tronics x3301 is a world-class Multispectrum Infrared (MIR) flame detector designed to provide superior performance in hydrocarbon-based fire detection. It utilizes patented algorithms and three sensors to evaluate multiple infrared wavelengths, ensuring the highest degree of false alarm rejection even in extreme industrial environments

Fill out the form below and we'll answer as soon as possible.

Key Features and Functional Benefits

Automatic Optical Integrity (oi): A calibrated performance test is performed every minute to verify the sensor’s functionality without requiring an external test lamp.
Environmental Resistance: Features heated optics to prevent condensation, icing, and desensitization in harsh weather or humidity.
Flexible Output Options: Includes standard fire, fault, and auxiliary relays, with optional 0-20 mA, HART, Pulse, or Eagle Quantum Premier (EQP) digital communication.
Data Logging: Events are time and date-stamped, recording alarms, faults, and temperature shifts for diagnostic reviews.
Application-Specific Modes:
    ◦ Hangar Mode: Implements a 7-9 second processing delay to ignore temporary friendly fires from aircraft auxiliary power units.
    ◦ Turbine Mode: Uses T-Low sensitivity for environments with elevated background IR energy like turbine enclosures

International Certifications


• Functional Safety: exida certified SIL 2 Capable (IEC 61508).
• Hazardous Areas:
◦ FM/CSA: Class I, Div 1 & 2; Class II/III, Div 1 & 2.
◦ ATEX/IECEx: Ex db eb IIC T6…T5 Gb; Ex tb IIIC T130°C Db.
• Maritime: DNV (MED) and USCG approved for offshore ships and production platforms.
• Performance: Certified to ANSI/FM 3260 and EN 54-10

Det-Tronics x3301 Multispectrum IR Flame Detector — FAQ

What is the x3301 multispectrum IR flame detector? The Det-Tronics X3301 is a multispectrum infrared (MIR) flame detector built for hazardous industrial environments. It uses three IR sensors and multi-patented signal processing algorithms — powered by a 32-bit microprocessor — to detect hydrocarbon fires fast while rejecting false alarms, even in high-IR-background environments like offshore platforms, refineries, and turbine enclosures.

 

What makes it one of the best multispectrum IR flame detectors for industry? SIL 2 certified, Division and Zone explosion-proof rated, and compatible with Modbus, HART, 0-20 mA, and EQP protocols. Its three-channel multispectrum analysis consistently outperforms single-spectrum UV or IR detectors in demanding environments.

 

How does the x3301 prevent false alarms? It analyses multiple IR wavelength bands simultaneously. Real hydrocarbon flames have a distinct spectral signature that the detector’s microprocessor distinguishes from arc welding, solar radiation, or hot surfaces. Optional Hangar Mode adds extended verification time for environments with intermittent IR sources.

 

What industries use the x3301? Offshore oil and gas, refineries, LNG/LPG terminals, compressor stations, turbine enclosures, aircraft hangars, automotive paint booths, loading racks, and pharmaceutical manufacturing — anywhere flammable hydrocarbons and hazardous area classification apply.

 

X3301 vs UV/IR flame detectors — what’s the difference? UV sensors are susceptible to arc welding and solar radiation and degrade in oily or humid atmospheres. The X3301’s all-IR multispectrum approach is more resilient in those conditions, achieves SIL 2, and covers a broader range of hydrocarbon fuels.

 

Who manufactures multispectrum IR flame detectors? Key manufacturers include Det-Tronics (X3301), Spectrex (SharpEye), Honeywell (FS24X), MSA Safety (FL5000), and General Monitors (FL4000H). Det-Tronics is among the most specified in oil and gas and aviation applications globally.

 

Where can I buy the x3301? Through authorised distributors and certified integrators. Blue BMS supplies and integrates the X3301 for industrial projects worldwide — supply-only or full system design, commissioning, and service. Request a quote →

 

X3301 installation best practices Mount at the correct height and angle for the 90° conical field of view. Eliminate detection shadows during design. Keep the optical window clean. Use hazardous-area-rated cable entries. Select the appropriate sensitivity level for your background IR environment. Commission with a certified test flame before handover.

 

What communication protocols does the X3301 support? Standard relay outputs (fire alarm, fault, auxiliary), RS-485 Modbus, 0-20 mA analogue, HART, pulse output, FDT/DTM, and Eagle Quantum Premier (EQP) for Det-Tronics native system integration.

Technical Specifications

See this products configurations: -X3301S4N13SB2 -X3301A4N14SB2 -X3301 HEAD, AL, EX DE, SIL -X3301 HEAD, SS, EX DE, SIL -X3301 HEAD, SS, EX D, SIL -X3301S4M14T2 -X3301S4M13K1 -X3301S4M23SK1

Here are some similar products for you