Fill out the form below and we'll answer as soon as possible.
The GT3000 Calibration Gas Kit is a complete, ready-to-use calibration solution engineered specifically for Det-Tronics GT3000 Series toxic gas detectors. Designed for safety instrumented systems (SIS) in oil and gas, petrochemical, and offshore environments, the GT3000 Calibration Gas Kit ensures your fixed gas detection equipment maintains certified accuracy and regulatory compliance between service intervals — with no improvised setups or sourcing of third-party components.
Each GT3000 Calibration Gas Kit ships factory-assembled and includes two cylinders of hydrogen sulfide (H₂S) in nitrogen balance at your specified concentration, a calibrated flow regulator set to 1 L/min, 3 ft of connection tubing, a calibration cup, and a rugged carrying case. Everything required for a complete calibration event is in a single package — reducing field preparation time and eliminating compatibility risk.
Three H₂S concentration options are available to match your detector configuration and site safety standard: 10 ppm (P/N 010274-001), 25 ppm (P/N 010274-002), and 50 ppm (P/N 010274-003). All versions use the same kit format, allowing standardised calibration procedures across multi-detector installations.
The GT3000 Calibration Gas Kit is suited for live maintenance environments in classified hazardous locations, including subsea infrastructure, offshore platforms, onshore refineries, and process facilities operating under ISA, IEC 61511, or equivalent safety management frameworks.
Blue BMS supplies the GT3000 Calibration Gas Kit globally with full export documentation, hazardous goods packaging, and fast lead times for oil and gas procurement timelines.
The GT3000 Calibration Gas Kit is certified for use with the full Det-Tronics GT3000 detector series. Each kit contains two H₂S cylinders in nitrogen balance — chosen to provide a backup cylinder on-site without an additional procurement cycle. The included regulator delivers a consistent 1 L/min flow rate to the calibration cup, which mates directly to the GT3000 detector head without adapters. The rugged carry case protects cylinder and accessories during transport to offshore or remote site locations.
Concentration options for the GT3000 Calibration Gas Kit cover the alarm range of most H₂S safety system configurations: 10 ppm is appropriate for lower-threshold monitoring (e.g., IDLH pre-alarm verification), 25 ppm covers the most common mid-range calibration setpoint, and 50 ppm is specified where high-alarm or full-scale verification is required.
The GT3000 Calibration Gas Kit is used across the following sectors:
Oil and Gas Platforms — H₂S monitoring and safety system compliance on fixed and floating installations. Petrochemical Plants and Refineries — fixed gas detection calibration within SIS and fire and gas (F&G) systems. Industrial and Process Facilities — periodic detector verification under ISA 84 / IEC 61511 maintenance requirements. Offshore and Onshore Installations — certified for use in hazardous classified locations.
GT3000 Calibration Gas Kit — P/N 010274-001 — H₂S 10 ppm — 2 cylinders — 11.5 lb GT3000 Calibration Gas Kit — P/N 010274-002 — H₂S 25 ppm — 2 cylinders — 11.5 lb GT3000 Calibration Gas Kit — P/N 010274-003 — H₂S 50 ppm — 2 cylinders — 11.5 lb
Contact Blue BMS with your part number, quantity, and delivery location to receive a formal quote with lead time and shipping documentation.
Why Source the GT3000 Calibration Gas Kit Through Blue BMS
Blue BMS is a specialist distributor for Det-Tronics fire and gas detection products, serving industrial and energy sector clients across the Americas, EMEA, and APAC. For the GT3000 Calibration Gas Kit specifically, Blue BMS provides competitive unit and volume pricing, fast procurement turnaround for planned and emergency maintenance schedules, full hazardous goods export documentation for international shipments, and access to Det-Tronics technical resources and post-sales support. Calibration scheduling and onsite servicing are available via partner networks on request.
The GT3000 Calibration Gas Kit is used to perform certified calibration of Det-Tronics GT3000 Series toxic gas detectors in the field. It provides a controlled concentration of H₂S gas at a known ppm level to verify detector response accuracy and maintain compliance with site safety management and regulatory requirements.
Which H₂S concentration should I specify for the GT3000 Calibration Gas Kit? Select the concentration that matches your detector’s calibration setpoint: 10 ppm (P/N 010274-001) for lower-threshold verification, 25 ppm (P/N 010274-002) for mid-range calibration, and 50 ppm (P/N 010274-003) for high-alarm or full-scale verification. If unsure, consult your GT3000 detector configuration documentation or contact Blue BMS.
Can the GT3000 Calibration Gas Kit be used for gases other than H₂S? No. The 010274-002 kit is formulated for H₂S in nitrogen balance. For other target gases, separate calibration kits apply — for example, P/N 010274-004 for chlorine (Cl₂). Contact Blue BMS to confirm the correct kit for your detector configuration.
What is the shelf life of the cylinders in the GT3000 Calibration Gas Kit? Shelf life depends on the specific cylinder batch and storage conditions. Consult Det-Tronics documentation supplied with the kit, or contact Blue BMS for current shelf-life data and cylinder replacement scheduling.
Does Blue BMS supply the GT3000 Calibration Gas Kit internationally? Yes. Blue BMS ships the GT3000 Calibration Gas Kit globally, including the Americas, Europe, Middle East, Africa, and Asia-Pacific, with full hazardous goods packaging, export documentation, and customs compliance support.